2. CHARACTERISTICS AND SPECIFICATIONS
(All Min/Max characteristics and specifications are guaranteed over the Specified Operating Conditions. Typical per-
formance characteristics and specifications are derived from measurements taken at nominal supply voltages and
T
A
= 25° C.)
RECOMMENDED OPERATING CONDITIONS
GND = 0 V, all voltages with respect to 0 V.
ABSOLUTE MAXIMUM RATINGS
DGND = AGND = 0 V; all voltages with respect to 0 V. Operation beyond these limits may result in permanent
damage to the device. Normal operation is not guaranteed at these extremes.
Notes:
1. Transient currents of up to 100 mA will not cause SCR latch-up.
Parameter Symbol Min Nominal Max Units
Power Supply Voltage
VL
VA
V_REG
1.71
3.135
3.135
3.3
3.30
3.30
5.25
3.465
3.465
V
V
V
Ambient Operating Temperature: Commercial Grade T
A
-40 - +85 °C
Parameter Symbol Min Max Units
Power Supply Voltage
VL
VA
V_REG
-0.3
-0.3
-0.3
6.0
4.3
4.3
V
V
V
Input Current, Any Pin Except Supplies (Note 1) I
in
10mA
Input Voltage, Any Pin Except RXP[1:0], RXN[1:0], or
RX[3:0]
V
in
-0.3 VL+0.4 V
Input Voltage, RXP[1:0], RXN[1:0], or RX[3:0] V
in
-0.3 VA+0.4 V
Ambient Operating Temperature (power applied) T
A
-55 +125 °C
Storage Temperature T
stg
-65 +150 °C