3. TYPICAL CONNECTION DIAGRAMS
Figure 5. Typical Connection Diagram, No External Master Clock
* When no external master clock is supplied to the part, both input and output must be set to Slave Mode for the
part to operate properly. This is done by connecting the MS_SEL pin to ground through a resistance of 0
to 1 k
+ 1% as stated in Table 1, “Serial Audio Port Master/Slave and Clock Ratio Select Start-Up Options (MS_SEL),”
on page 18.
** The connection (VL or GND) and value of these two resistors determines the mode of operation for the input and
output serial ports as described in Table 2 on page 18 and Table 3 on page 18.
*** This pin must not be pulled high. See Section 1, “Pin Descriptions.”