Cirrus-logic CS8406 Instrukcja Użytkownika Strona 8

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 39
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 7
8 DS580F6
CS8406
SWITCHING CHARACTERISTICS - CONTROL PORT - I²C MODE
(Inputs: Logic 0 = 0 V, Logic 1 = VL; C
L
= 20 pF)
13. Data must be held for sufficient time to bridge the 300 ns transition time of SCL.
Parameter Symbol Min Typ Max Units
SCL Clock Frequency fscl - - 100 kHz
Bus Free Time Between Transmissions t
buf
4.7 - - s
Start Condition Hold Time (prior to first clock pulse) t
hdst
4.0 - - s
Clock Low Time t
low
4.7 - - s
Clock High Time t
high
4.0 - - s
Setup Time for Repeated Start Condition t
sust
4.7 - - s
SDA Hold Time from SCL Falling (Note 13) t
hdd
0--s
SDA Setup Time to SCL Rising t
sud
250 - - ns
Rise Time of Both SDA and SCL Lines t
r
- - 1000 ns
Fall Time of Both SDA and SCL Lines t
f
- - 300 ns
Setup Time for Stop Condition t
susp
4.7 - - s
Figure 4. I²C Mode Timing
Przeglądanie stron 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 38 39

Komentarze do niniejszej Instrukcji

Brak uwag