Cirrus-logic CS61584A Instrukcja Użytkownika Strona 39

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 54
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 38
CS61584A
DS261PP5 39
DS261PP5
11.PIN DESCRIPTIONS
Power Supplies
AGND - Analog Ground (PLCC pin 33; TQFP pin 23)
Analog supply ground pin.
AV+ - Analog Power Supply (PLCC pin 34; TQFP pin 24)
Analog supply pin for internal bandgap reference, oscillator, and timing generation circuits.
BGREF - Bandgap Reference (PLCC pin 32; TQFP pin 22)
This pin is used by the internal bandgap reference and must be connected to ground by a 4.99 k ±1%
resistor to provide an internal current reference.
DGND1, DGND2, DGND3 - Digital Ground (PLCC pins 1, 18, 67; TQFP pins 57, 9, 55)
Power supply ground pins for the digital circuitry of both channels.
DV+ - Digital Power Supply (PLCC pin 68; TQFP pin 56)
Power supply pin for the digital circuitry of both channels.
41
43
45
47
33
35
37
39
7
5
3
1
15
13
11
9
17 19 21 23 25 27 29 31
63 61 59 57 55 53 51 49
8
6
4
2
16
14
12
10
18 20 22 24 26 28 30 32
42
44
46
48
34
36
38
40
64 62 60 58 56 54 52 50
CS61584A
64-pin TQFP
Top View
DGND1
AD3
AD2
AD1
TGND1
TRING1
SAD4
P/S
RTIP1
RRING1
RV+1
RGND1
DGND2
J-TDI
TTIP1
TV+1
TPOS1(TDATA1)
TNEG1(AIS1)
SAD6
J-TDO
RCLK1
RPOS1(RDATA1)
RNEG1(BPV1)
TCLK1
AD0
RD(DS)
INT
CS
MODE
BGREF
AGND
AV+
DGND1
not used
SPOL
SDI
TGND1
TRING1
ZTX1
P/S
RTIP1
RRING1
RV+1
RGND1
DGND2
J-TDI
TTIP1
TV+1
TPOS1(TDATA1)
TNEG1(AIS1)
LOS1
J-TDO
RCLK1
RPOS1(RDATA1)
RNEG1(BPV1)
TCLK1
SDO
SCLK
INT
CS
MODE
BGREF
AGND
AV+
DGND1
CON01
TAOS2
TAOS1
TGND1
TRING1
PD1
ATTEN0
RTIP1
RRING1
RV+1
RGND1
DGND2
J-TDI
TTIP1
TV+1
TPOS1
TNEG1
LOS1
J-TDO
RCLK1
RPOS1
RNEG1
TCLK1
LLOOP
RLOOP2
RLOOP1
ATTEN1
MODE
BGREF
AGND
AV+
Hardware Mode
Host Mode
Serial Port
Host Mode
Parallel Port
DV+
DGND3
CON02
CON11
CON12
CON21
CON22
CON31
RCLK2
RPOS2
RNEG2
TCLK2
TPOS2
TNEG2
LOS2
CON32
J-TCK
J-TMS
TTIP2
TV+2
TGND2
TRING2
PD2
CLKE
RTIP2
RRING2
RV+2
RGND2
1XCLK
XTALOUT
REFCLK
RESET
DV+
DGND3
not used
not used
not used
not used
not used
not used
RCLK2
RPOS2(RDATA2)
RNEG2(BPV2)
TCLK2
TPOS2(TDATA2)
TNEG2(AIS2)
LOS2
not used
J-TCK
J-TMS
TTIP2
TV+2
TGND2
TRING2
ZTX2
IPOL
RTIP2
RRING2
RV+2
RGND2
1XCLK
XTALOUT
REFCLK
RESET
DV+
DGND3
AD4
AD5
AD6
AD7
ALE(AS)
WR(R/W)
RCLK2
RPOS2(RDATA2)
RNEG2(BPV2)
TCLK2
TPOS2(TDATA2)
TNEG2(AIS2)
SAD7
BTS
J-TCK
J-TMS
TTIP2
TV+2
TGND2
TRING2
SAD5
IPOL/DTACK
RTIP2
RRING2
RV+2
RGND2
1XCLK
XTALOUT
REFCLK
RESET
Hardware Mode
Host Mode
Serial Port
Host Mode
Parallel Port
Pins labeled as “not used” should be tied to ground.
CS61584A