Cirrus-logic CDB5532U Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Cirrus-logic CDB5532U. Cirrus Logic CDB5532U User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 22
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Copyright © Cirrus Logic, Inc. 2007
(All Rights Reserved)
http://www.cirrus.com
AIN1+
AIN1-
AIN2+
AIN2-
CRYSTAL
4.9152 MHz
CS5532
A1
A0
SCLK
SDO
SDI
CS
C8051F320
Microcontroller
RESET
CIRCUITRY
Interface Header
AIN1+
AIN1-
AIN2+
AIN2-
VREF-
VREF+
VREF
Source
Select
LT1019
VREF+
VREF-
VD+
VA- VA+
GND
+5 V
USB
CONNECTOR
CDB5532U
CDB5532U Evaluation Board and Software
Features
USB Communication with PC
On-board Microcontroller
On-board Voltage Reference
Evaluation Software
Register Setup & Chip Control
FFT Analysis
Time Domain Analysis
Noise Histogram Analysis
Interface Header for External Microcontroller
General Description
The CDB5532U is an inexpensive tool designed to eval-
uate the functionality and performance of the CS5532.
The CS5532 datasheet should be read and consulted
when using the CDB5532U evaluation board.
The evaluation board includes a C8051F320 microcon-
troller with a USB interface. The microcontroller controls
the serial communication between the evaluation board
and the PC via the firmware, enabling quick and easy ac-
cess to all of the CS5532’s registers and functions.
The CDB5532U includes software for data capture, time
domain analysis, histogram analysis, and frequency do-
main analysis.
ORDERING INFORMATION
CDB5532U Evaluation Board
AUG ‘07
DS807DB1
Przeglądanie stron 0
1 2 3 4 5 6 ... 21 22

Podsumowanie treści

Strona 1 - CDB5532U

Copyright © Cirrus Logic, Inc. 2007(All Rights Reserved)http://www.cirrus.comAIN1+AIN1-AIN2+AIN2-CRYSTAL4.9152 MHzCS5532A1A0SCLKSDOSDICSC8051F320Micro

Strona 2

CDB5532U10 DS807DB12.2.3 Data Collection WindowThe Data Collection window (Figure 5) allows the user to collect sample sets of data from the CS5532 an

Strona 3

CDB5532UDS807DB1 112.2.4 Configuration WindowThe Configuration window allows the user to set up the data collection and analysis parameters. See Fig-u

Strona 4

CDB5532U12 DS807DB12.3 Collecting Data SetsTo collect a sample data set:1) In the Data Collection window, select the Config button to bring up the Con

Strona 5

CDB5532UDS807DB1 132.7 Histogram InformationThe following is a description of the indicators associated with histogram analysis. Histograms can be plo

Strona 6

CDB5532U14 DS807DB13. SCHEMATICS Figure 7. Analog Section

Strona 7

CDB5532UDS807DB1 15 Figure 8. Digital Section

Strona 8

CDB5532U16 DS807DB1Figure 9. Power Supply

Strona 9

CDB5532UDS807DB1 174. BOARD LAYOUT Figure 10. Top Silkscreen

Strona 10

CDB5532U18 DS807DB1 Figure 11. Top Routing

Strona 11

CDB5532UDS807DB1 19 Figure 12. Bottom Routing

Strona 12

CDB5532U2 DS807DB1TABLE OF CONTENTS1. HARDWARE ...

Strona 13

CDB5532U20 DS807DB1 Figure 13. Bottom Silkscreen

Strona 14

CDB5532UDS807DB1 21NOTES

Strona 15

CDB5532U22 DS807DB1REVISION HISTORY Revision Date ChangesDB1 AUG 2007 Initial release.Contacting Cirrus Logic SupportFor a complete listin

Strona 16

CDB5532UDS807DB1 31. HARDWARE1.1 IntroductionThe CDB5532U evaluation board provides a quick means of evaluating the CS5532 Analog-to-DigitalConverter

Strona 17

CDB5532U4 DS807DB1Table 1. Voltage Reference Selection for VREF+ Table 2. Voltage Reference Selection for VREF- 1.2.2 Digital SectionFigure 8 illustra

Strona 18

CDB5532UDS807DB1 52. SOFTWAREThe evaluation board comes with software and a USB cable to link the evaluation board to the PC. Thesoftware is designed

Strona 19

CDB5532U6 DS807DB12.2.1 Start-Up WindowWhen the evaluation program is launched, the start-up window will appear. This window contains infor-mation con

Strona 20

CDB5532UDS807DB1 72.2.1.2 Window MenuAfter the user selects the appropriate setup, the Window option becomes available in the Start-up window.The Wind

Strona 21

CDB5532U8 DS807DB1Read Data: This button will instruct the ADC to begin performing repeated single (fully-settled) conver-sions on the setup channel s

Strona 22

CDB5532UDS807DB1 9Calibration Window: The Calibration window (Figure 4) permits the user to access the calibration regis-ters for each channel of the

Komentarze do niniejszej Instrukcji

Brak uwag